DragonFly On-Line Manual Pages
coax(1) DragonFly General Commands Manual coax(1)
NAME
coax - determine impedance of a coaxial structure, where the inner may
be offset from the centre if necessary.
SYNOPSIS
coax [-O offset] d D Er
DESCRIPTION
coax computes the impedance of a coaxial cable, given the outside
diameter of the inner conductor d, the internal diameter of the outer
conductor D and the relative permittivity of the dielectric Er. If
there is an offset between the inner and outer (i.e. the coax is
eccentric), the offset can be given as a option. coax uses the equation
Zo=59.95849160 ln(x+sqrt(x^2-1)) /sqrt(Er) Ohms
where x=(d^2+D^2-4 O^2)/(2*D*d)
FILES
coax does not read/write any files.
SEE ALSO
atlc(1)
create_bmp_for_circ_in_circ(1)
create_bmp_for_circ_in_rect(1)
create_bmp_for_microstrip_coupler(1)
create_bmp_for_rect_cen_in_rect(1)
create_bmp_for_rect_cen_in_rect_coupler(1)
create_bmp_for_rect_in_circ(1)
create_bmp_for_rect_in_rect(1)
create_bmp_for_stripline_coupler(1)
create_bmp_for_symmetrical_stripline(1)
design_coupler(1)
dualcoax(1)
find_optimal_dimensions_for_microstrip_coupler(1)
readbin(1)
http://atlc.sourceforge.net - Home page
http://sourceforge.net/projects/atlc - Download area
/usr/local/share/atlc/docs/html-docs/index.html - HTML docs
/usr/local/share/atlc/docs/qex-december-1996/atlc.pdf - theory paper
/usr/local/share/atlc/examples - examples
Dr. David Kirkby atlc-4.6.0 28th Oct 2003 coax(1)