DragonFly On-Line Manual Pages
HEALTHDC(8) DragonFly System Manager's Manual HEALTHDC(8)
NAME
healthdc - Motherboard "health" monitor
SYNOPSIS
healthdc [-H|h] [-P port] [-V] [-d] [-t|v] [host ...]
DESCRIPTION
This program provides a facility to read the current values from local
and remote healthd(8) programs. This allows monitoring of all networked
computers for critical hardware failures. Healthdc can be run from other
programs or scripts to automatically log the current values and watch for
trends.
OPTIONS
The following command line options are available.
-H HTML Output. This will produce a full HTML page with a table
for each host specified on the command line.
-P port Use a different port then the default 1281. This is a
different port than previous versions. The older versions
used 9669, however 1281 is the official port number.
-V Display the current version and exit.
-d Display extra debugging info. Not implemented yet.
-h HTML output, without headers. This functions in a similar
fashion to -H except the output is missing the <HTML>,
<HEAD>, and <BODY> start and end tags. This is intended to
be used within another HTML page.
-t Display the output in a tab delimited line. The order of the
output is hostname, temp1, temp2, temp3, fan1, fan2, fan3,
Vcore1, Vcore2, 3volt, +5Volt, +12Volt, -12Volt and -5Volt.
-v This displays a comma delimited list with all stats about
each of the monitored parameters. This includes, in addition
to the current value, whether it is active, the number of
out-of-bounds readings, if a failure has been logged and if a
warning has been logged. The order of the output is
hostname, temp1, temp2, temp3, fan1, fan2, fan3, Vcore1,
Vcore2, 3volt, +5Volt, +12Volt, -12Volt and -5Volt.
host ... The host, or hosts, to get the current readings from. If not
specified localhost is used.
FreeBSD August 16, 2004 FreeBSD